Malachite green and crystal violet, once widely used inaquaculture for their low cost and antibacterial properties,can pose health risks due to their toxicity and accumulationin organisms.
Biocomma established a UPLC-MS/MS method for detectionof malachite green and crystal violet in shrimp by Copure®ALN Neutral Alumina Cartridges with good recovery andprecision for your reference. The recoveries were 90-110%with RSD less than 5%.

Experiment
Extraction
Weigh 5.00 g of ground shrimp into a clean centrifuge tube.Add 400 μL of mixed internal standard (malachite green-d5and leuco-malachite green-d6) and 11 mL of acetonitrile.Extract by ultrasonic treatment for 2.0 min, then vortex at2500 rpm for 5.0 min. Centrifugation at 8000 r/min for 5.0min. Transfer the supernatant to another 50 mL centrifugetube. Repeat the extraction procedures. Combine thesupernatant and dilute to 25 mL by acetonitrile. The sampleis ready for purification.
Purification(Copure® ALN Neutral Alumina Cartridges, 1 g/ 3 mL)
Activation: activate the cartridge by 5.0 mL of acetonitrile.Loading: add the prepared solution to the SPE cartridge.Washing: wash the cartridge by 4.0 mL of acetonitrile.
Elution: evaporate to dryness at 45 °C. Add 1.0 mL ofacetonitrile, and sonicate for 5.0 min. then, add 1.0 mL of 5mmol/L ammonium acetate, and sonicate for 1.0 min. Afterfilter by 0.22 μm filter membrane, the sample is ready forLC-MS/MS analysis.
Preparation of Matrix Blank
Prepare blank sample in the same procedures.
Instrument Conditions
1.Chromatographic Conditions
Instrument: UPLC-MS/MS (Thermo Fisher TSQ Endura)Chromatographic column: Commasil® Coreshell C18 (2.1mm×100 mm, 1.7 μm)Mobile phase: A: water (0.1% formic acid), B: acetonitrile(0.1% formic acid)Flow rate: 0.3 mL/ minColumn temperature: 30 ℃
Injection volume: 10 μL
Table 1. Gradient Elution Program

2.Mass Spectrometry Conditions
Ion source: HESI
Electrospray voltage: 3500 V
Sheath gas pressure:15 arb
Auxiliary gas pressure: 1 arb
Ion exchange tube: 360 ℃
Auxiliary air temperature: 380 ℃
Table 2. Targets, Retention Times and CharacteristicIons (*Quantifier Ion)


Table 3 Results of Spiked Recoveries of in Shrimp

Table 3 Results of Spiked Recoveries of in Shrimp